Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Main subject
Language
Document Type
Year range
1.
Clin Infect Dis ; 73(Suppl_5): S454-S464, 2021 12 15.
Article in English | MEDLINE | ID: covidwho-1577471

ABSTRACT

BACKGROUND: Minimally invasive tissue sampling (MITS), a postmortem procedure that uses core needle biopsy samples and does not require opening the body, may be a valid alternative to complete autopsy (CA) in highly infectious diseases such as coronavirus disease-19 (COVID-19). This study aimed to (1) compare the performance of MITS and CA in a series of COVID-19 deaths and (2) evaluate the safety of the procedure. METHODS: From October 2020 to February 2021, MITS was conducted in 12 adults who tested positive before death for COVID-19, in a standard, well-ventilated autopsy room, where personnel used reinforced personal protective equipment. In 9 cases, a CA was performed after MITS. A thorough histological evaluation was conducted, and the presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was evaluated by real-time reverse-transcription polymerase chain reaction (RT-PCR) and immunohistochemistry. RESULTS: The diagnoses provided by MITS and CA matched almost perfectly. In 9 patients, COVID-19 was in the chain of events leading to death, being responsible for diffuse alveolar damage and mononuclear T-cell inflammatory response in the lungs. No specific COVID-19 features were identified. Three deaths were not related to COVID-19. All personnel involved in MITS repeatedly tested negative for COVID-19. SARS-CoV-2 was identified by RT-PCR and immunohistochemistry in the MITS samples, particularly in the lungs. CONCLUSIONS: MITS is useful for evaluating COVID-19-related deaths in settings where a CA is not feasible. The results of this simplified and safer technique are comparable to those of CA.


Subject(s)
COVID-19 , Autopsy , Humans , Personal Protective Equipment , Real-Time Polymerase Chain Reaction , SARS-CoV-2
2.
Pathogens ; 10(4)2021 Apr 01.
Article in English | MEDLINE | ID: covidwho-1167681

ABSTRACT

Postmortem studies are crucial for providing insight into emergent diseases. However, a complete autopsy is frequently not feasible in highly transmissible diseases due to biohazard challenges. Minimally invasive autopsy (MIA) is a needle-based approach aimed at collecting samples of key organs without opening the body, which may be a valid alternative in these cases. We aimed to: (a) provide biosafety guidelines for conducting MIAs in COVID-19 cases, (b) compare the performance of MIA versus complete autopsy, and (c) evaluate the safety of the procedure. Between October and December 2020, MIAs were conducted in six deceased patients with PCR-confirmed COVID-19, in a basic autopsy room, with reinforced personal protective equipment. Samples from the lungs and key organs were successfully obtained in all cases. A complete autopsy was performed on the same body immediately after the MIA. The diagnoses of the MIA matched those of the complete autopsy. In four patients, COVID-19 was the main cause of death, being responsible for the different stages of diffuse alveolar damage. No COVID-19 infection was detected in the personnel performing the MIAs or complete autopsies. In conclusion, MIA might be a feasible, adequate and safe alternative for cause of death investigation in COVID-19 cases.

SELECTION OF CITATIONS
SEARCH DETAIL